HPLC Flow Counting

Radiolabeled materials are often analyzed by chromatography. The original application of liquid scintillation counting to chromatographic techniques was to collect and count discrete fractions. This manner of counting is extremely laborious, and resolution is limited by the size of the fractions collected. Flow detectors were introduced to allow continuous LSC monitoring of column effluents. This gives extremely high resolution results that are simultaneous with the separation. Modern flow detectors also have a switchable outflow, allowing radioactive peaks in the chromatogram to be collected for further analysis, or simply to sequester radioactive from nonradioactive waste.
HPLC Flow Detector
HPLC Flow Detector

Flow detectors operate by passing a mixture of column effluent and scintillation cocktail through a transparent or translucent channel, which is monitored by a photomultiplier tube. The flow rates of effluent and cocktail are metered to provide a constant ratio, and the channel (generally a plastic tube) is coiled to cover the entire window area of the PMT. Cocktails for flow LSC must provide for high efficiency, high sample capacity, and low viscosity. High efficiency allows for more sensitive detection, and minimizes any decrease in signal due to sample composition or detector geometry.

The sample capacity is important because flow LSC tends to generate surprising amounts of waste materials. A typical HPLC flow rate is 1ml/min. Over an 8 hour day, continuous use of such a system will generate 1 X 60 X 8=480ml of spent solvent. If a low capacity cocktail is used (one which requires 10 volumes of cocktail per volume of sample), up to 5 liters of waste will be produced. Use of a high capacity cocktail (3:1, 2:1 or even 1:1 with National Diagnostics' Ecoscint Flow) will reduce this amount by up to 70% and keep disposal costs under control. Because of the large amounts of cocktail used, switching of labeled peaks to a separate waste collection and using a biodegradable cocktail are recommended.


0
Products Related to this Discussion:
Ecoscint Flow
The best all around cocktail for HPLC flow counting. Biodegradable, low viscosity, ultra-high sample-hold flow cocktail.
Uniscint BD
Biodegradable scintillation solution especially formulated to accommodate high salt.
Monoflow 1
For use with flow detectors for organic soluble samples, such as lipids and steroids.
Monoflow 2
A high efficiency scintillation solution for use with flow detectors.
Monoflow 3
Scintillation cocktail for use with flow detectors. Specifically designed for highly aqueous samples up to ratios of 2:1 scintillator to sample.
Monoflow 4
Liquid scintillation cocktail for HPLC effluents containing high salt concentrations.
Monoflow 5
Biodegradable liquid scintillator of low toxicity for HPLC effluents counted in flow detectors at 3:1 cocktail to sample.

REQUEST A CATALOG

CURRENCIES

NEW PRODUCTS

UreaGel 29:1 Denaturing Gel System

Allows researchers to easily and safely produce denatururing gels of 29:1 acrylamide: bisacrylamide formula in concentrates up to 20% monomer.
Read more...


ProtoGel Sample Prep Kit

An easy-to-use, inexpensive kit that allows for pure samples and more concentrated SDS-PAGE samples.
Read more...


UreaGel Loading Buffer

Denaturing loading buffer for UreaGel as well as other denaturing polyacrylamide gel applications
Read more...

































Copyright © 2010 National Diagnostics. All rights reserved.
Please read our policies on privacy and shipping & returns.  Contact Us.
Powered by OS Commerce